Sungrow

Supported models
  • Logger1000
  • Logger1000A/B
  • Logger3000
  • Logger3000B
  • Logger4000
  • COM100A
  • COM100D/E
  • WiNet-S
  • SG10KTL
  • SG10KTL
  • SG12KTL
  • SG15KTL
  • SG20KTL
  • SG30KU
  • SG36KTL
  • SG36KU
  • SG40KTL
  • SG40KTL-M
  • SG50KTL-M
  • SG60KTL-M
  • SG60KU
  • SG30KTL-M
  • SG30KTL-M-V31
  • SG33KTL-M
  • SG36KTL-M
  • SG33K3J
  • SG49K5J
  • SG34KJ
  • LP_P34KSG
  • SG50KTL-M-20
  • SG60KTL
  • SG80KTL
  • SG80KTL-20
  • SG60KU-M
  • SG5KTL-MT
  • SG6KTL-MT
  • SG8KTL-M
  • SG10KTL-M
  • SG10KTL-MT
  • SG12KTL-M
  • SG15KTL-M
  • SG17KTL-M
  • SG20KTL-M
  • SG80KTL-M
  • SG111HV
  • SG125HV
  • SG125HV-20
  • SG30CX
  • SG33CX
  • SG36CX-US
  • SG40CX
  • SG50CX
  • SG60CX-US
  • SG49.5CX-JP
  • SG110CX
  • SG250HX
  • SG250HX-US
  • SG100CX
  • SG100CX-JP
  • SG250HX-IN
  • SG25CX-SA
  • SG75CX
  • SG3.0RT
  • SG4.0RT
  • SG5.0RT
  • SG6.0RT
  • SG7.0RT
  • SG8.0RT
  • SG12RT
  • SG15RT
  • SG17RT
  • SG20RT
  • SG5.5RS-JP
  • SG125HX-JP
  • SG320HX
  • SG350HX
  • SG125CX-P2
  • SG25CX-P2
  • SG30CX-P2
  • SG33CX-P2
  • SG36CX-P2
  • SG40CX-P2
  • SG50CX-P2
  • SG10KTL
  • SG12KTL
  • SG15KTL
  • SG20KTL
  • SG30KU
  • SG36KTL
  • SG36KU
  • SG40KTL
  • SG40KTL-M
  • SG50KTL-M
  • SG60KTL-M
  • SG60KU
  • SG30KTL-M
  • SG30KTL-M-V31
  • SG33KTL-M
  • SG36KTL-M
  • SG33K3J
  • SG49K5J
  • SG34KJ
  • LP_P34KSG
  • SG50KTL-M-20
  • SG60KTL
  • SG80KTL
  • SG80KTL-20
  • SG60KU-M
  • SG5KTL-MT
  • SG6KTL-MT
  • SG8KTL-M
  • SG10KTL-M
  • SG10KTL-MT
  • SG12KTL-M
  • SG15KTL-M
  • SG17KTL-M
  • SG20KTL-M
  • SG80KTL-M
  • SG111HV
  • SG125HV
  • SG125HV-20
  • SG30CX
  • SG33CX
  • SG36CX-US
  • SG40CX
  • SG50CX
  • SG60CX-US
  • SG49.5CX-JP
  • SG110CX
  • SG250HX
  • SG250HX-US
  • SG100CX
  • SG100CX-JP
  • SG250HX-IN
  • SG25CX-SA
  • SG75CX
  • SG3.0RT
  • SG4.0RT
  • SG5.0RT
  • SG6.0RT
  • SG7.0RT
  • SG8.0RT
  • SG12RT
  • SG15RT
  • SG17RT
  • SG20RT
  • SG5.5RS-JP
  • SG125HX-JP
  • SG320HX
  • SG350HX
  • SG125CX-P2
  • SG25CX-P2
  • SG30CX-P2
  • SG33CX-P2
  • SG36CX-P2
  • SG40CX-P2
  • SG50CX-P2

Modbus TCP over ethernet

Warning

These steps are tailored to the Sungrow Logger1000A. They might deviate slightly for different SmartLogger types.

  1. Connect the ethernet cable between the ETH1 port of the Teleport and the LAN port of the Sungrow Logger. If the LAN port of the logger is already occupied (e.g. connected to a router), navigate to our appendix for instructions on how to integrate with a router.
  2. Log in to the Logger web UIopen in new window as explained in the commissioning process and go to System and then choose Port Parameter.
    1. If no router is present, go to Ethernet and set the Automatically obtain IP settings (DHCP) parameter to Close. Fill in the following information:
    • IP Address: 192.168.0.10
    • Subnet Mask: 255.255.255.0
    • Gateway: 0.0.0.0
    1. Go to Power Control and select Active Power to enter the active power interface. Set the Active Control Mode mode to Remote power control and verify these settings:
    • Power Limit in Case of Meter Communication Anomaly (%): 100.0
    • Control Method: Open-loop Control
    • Query recovery time(0~60)s: 0
    • Frame delay (4~70)ms: 18
    1. click save