Sungrow
Supported models
Logger1000
Logger1000A/B
Logger3000
Logger3000B
Logger4000
COM100A
COM100D/E
WiNet-S
SG10KTL
SG10KTL
SG12KTL
SG15KTL
SG20KTL
SG30KU
SG36KTL
SG36KU
SG40KTL
SG40KTL-M
SG50KTL-M
SG60KTL-M
SG60KU
SG30KTL-M
SG30KTL-M-V31
SG33KTL-M
SG36KTL-M
SG33K3J
SG49K5J
SG34KJ
LP_P34KSG
SG50KTL-M-20
SG60KTL
SG80KTL
SG80KTL-20
SG60KU-M
SG5KTL-MT
SG6KTL-MT
SG8KTL-M
SG10KTL-M
SG10KTL-MT
SG12KTL-M
SG15KTL-M
SG17KTL-M
SG20KTL-M
SG80KTL-M
SG111HV
SG125HV
SG125HV-20
SG30CX
SG33CX
SG36CX-US
SG40CX
SG50CX
SG60CX-US
SG49.5CX-JP
SG110CX
SG250HX
SG250HX-US
SG100CX
SG100CX-JP
SG250HX-IN
SG25CX-SA
SG75CX
SG3.0RT
SG4.0RT
SG5.0RT
SG6.0RT
SG7.0RT
SG8.0RT
SG12RT
SG15RT
SG17RT
SG20RT
SG5.5RS-JP
SG125HX-JP
SG320HX
SG350HX
SG125CX-P2
SG25CX-P2
SG30CX-P2
SG33CX-P2
SG36CX-P2
SG40CX-P2
SG50CX-P2
Modbus TCP over ethernet
Warning
These steps are tailored to the Sungrow Logger1000A. They might deviate slightly for different SmartLogger types.
- Connect the ethernet cable between the ETH1 port of the Teleport and the LAN port of the Sungrow Logger. If the LAN port of the logger is already occupied (e.g. connected to a router), navigate to our appendix for instructions on how to integrate with a router.
- Log in to the Logger web UI as explained in the commissioning process and go to System and then choose Port Parameter.
- If no router is present, go to Ethernet and set the Automatically obtain IP settings (DHCP) parameter to
Close
. Fill in the following information:
- IP Address:
192.168.0.10
- Subnet Mask:
255.255.255.0
- Gateway:
0.0.0.0
- Go to Power Control and select Active Power to enter the active power interface. Set the Active Control Mode mode to Remote power control and verify these settings:
- Power Limit in Case of Meter Communication Anomaly (%):
100.0
- Control Method:
Open-loop Control
- Query recovery time(0~60)s:
0
- Frame delay (4~70)ms:
18
- click save
- If no router is present, go to Ethernet and set the Automatically obtain IP settings (DHCP) parameter to