The Teleport can connect to Huawei SmartLoggers with system requirements as described in the SmartLogger Modbus Interface Definitions document. The Teleport can also connect to Huawei Inverters with system requirements as described in the Solar Inverter Modbus Interface Definitions document. You can connect using Modbus TCP over ethernet (recommended for SmartLoggers) or Modbus RTU using the RS485 serial interface (recommended for inverters).

Supported models
  • Model - Earliest Firmware Version
  • Logger3000A
  • Logger3000B
  • Logger1000A
  • COM100E (Logger1000B)
  • SDongleA-05 (connected to a supported inverter in this list) - V100R001C00
  • SUN2000-2KTL-L0 - SUN2000L V100R001C00
  • SUN2000-2KTL-L1 - SUN2000L V200R001C00
  • SUN2000-3KTL-CNL0 - SUN2000L V100R001C20
  • SUN2000-3KTL-L0 - SUN2000L V100R001C00
  • SUN2000-3KTL-L1 - SUN2000L V200R001C00
  • SUN2000-3KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-3KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-3.68KTL-L10 - SUN2000L V200R001C0
  • SUN2000-3.8KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-3.8KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-4KTL-CNL0 - SUN2000L V100R001C20
  • SUN2000-4KTL-L0 - SUN2000L V100R001C00
  • SUN2000-4KTL-L1 - SUN2000L V200R001C00
  • SUN2000-4KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-4KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-4.6KTL-L1 - SUN2000L V200R001C00
  • SUN2000-4.95KTL-JPL0 - SUN2000L V100R001C20
  • SUN2000-4.95KTL-JPL1 - SUN2000L V200R001C00
  • SUN2000-5KTL-CNL0 - SUN2000L V100R001C20
  • SUN2000-5KTL-L0 - SUN2000L V100R001C00
  • SUN2000-5KTL-L1 - SUN2000L V200R001C00
  • SUN2000-5KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-5KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-5KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-5KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-5KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-6KTL-CNL0 - SUN2000L V100R001C20
  • SUN2000-6KTL-L1 - SUN2000L V200R001C00
  • SUN2000-6KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-6KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-6KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-7.6KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-7.6KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-8KTL - SUN2000 V100R001
  • SUN2000-8KTL - SUN2000MA V100R001C10
  • SUN2000-8KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-8KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-8KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-8KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-8KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-9KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-9KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-10KTL - SUN2000 V100R001
  • SUN2000-10KTL - SUN2000MA V100R001C10
  • SUN2000-10KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-10KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-10KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-10KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-10KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-10KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-10KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-11.4KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-11.4KTL-USL0 - SUN2000L V100R001C10
  • SUN2000-12KTL - SUN2000 V100R001
  • SUN2000-12KTL - SUN2000MA V100R001C10
  • SUN2000-12KTL-M0 - SUN2000MA V100R001C00
  • SUN2000-12KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-12KTL-M1 - SUN2000MA V100R001C00
  • SUN2000-12KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-15KTL - SUN2000 V100R001
  • SUN2000-15KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-15KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-15KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-15KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-17KTL - SUN2000 V100R001
  • SUN2000-17KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-17KTL-M0 - SUN2000MA V100R001C10
  • SUN2000-17KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-17KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-20KTL - SUN2000 V100R001
  • SUN2000-20KTL-M0 - SUN2000MA V100R001C10SUN2000MA
  • SUN2000-20KTL-M0 - SUN2000MA V100R001C10SUN2000MA
  • SUN2000-20KTL-M2 - SUN2000MA V100R001C10
  • SUN2000-20KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-20KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-22KTL-US - SUN2000 V200R001C02
  • SUN2000-23KTL - SUN2000 V100R001
  • SUN2000-23KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-24.5KTL - SUN2000 V100R001
  • SUN2000-24.5KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-24.7KTL-JP - SUN2000 V200R002C00
  • SUN2000-25KTL-NAM3 - SUN2000MA V100R001C20
  • SUN2000-25KTL-US - SUN2000 V200R001C02
  • SUN2000-28KTL - SUN2000 V100R001
  • SUN2000-28KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-29.9KTL - SUN2000 V200R002C00
  • SUN2000-29.9KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-29.9KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-30KTL-A - SUN2000 V200R001C90
  • SUN2000-30KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-30KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-30KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-30KTL-NAM3 - SUN2000MA V100R001C20
  • SUN2000-30KTL-US - SUN2000 V200R001C02
  • SUN2000-33KTL - SUN2000 V200R001C90
  • SUN2000-33KTL-A - SUN2000 V200R002C00
  • SUN2000-33KTL-E001 - SUN2000 V200R001C90
  • SUN2000-33KTL-JP - SUN2000 V200R002C00
  • SUN2000-33KTL-NAM3 - SUN2000MA V100R001C20
  • SUN2000-33KTL-NHM3 - SUN2000MA V100R001C20
  • SUN2000-33KTL-US - SUN2000 V200R002C20
  • SUN2000-36KTL - SUN2000 V200R002C00
  • SUN2000-36KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-36KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-36KTL-NAM3 - SUN2000MA V100R001C20
  • SUN2000-36KTL-US - SUN2000 V200R002C20
  • SUN2000-40KTL - SUN2000 V200R001C90
  • SUN2000-40KTL-JP - SUN2000 V200R002C00
  • SUN2000-40KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-40KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-40KTL-NAM3 - SUN2000MA V100R001C20
  • SUN2000-40KTL-NHM3 - SUN2000MA V100R001C20
  • SUN2000-40KTL-US - SUN2000 V200R002C20
  • SUN2000-42KTL - SUN2000 V200R002C00
  • SUN2000-42KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-43KTL-IN-C1 - SUN2000 V200R002C00
  • SUN2000-43KTL-INM3 - SUN2000MA V100R001C20
  • SUN2000-44KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-45KTL-US-HV-D0 - SUN2000HA V100R001
  • SUN2000-50KTL - SUN2000 V200R002C00
  • SUN2000-50KTL-C1 - SUN2000 V200R002C00
  • SUN2000-50KTL-JPM0 - SUN2000 V300R001C00
  • SUN2000-50KTL-JPM1 - SUN2000 V300R001C00
  • SUN2000-50KTL-M0 - SUN2000 V300R001C00
  • SUN2000-50KTL-M3 - SUN2000MA V100R001C20
  • SUN2000-55KTL-HV-D1 - SUN2000HA V100R001
  • SUN2000-55KTL-HV-D1-001 - SUN2000HA V100R001
  • SUN2000-55KTL-IN-HV-D1 - SUN2000HA V100R001
  • SUN2000-60KTL-HV-D1 - SUN2000HA V100R001
  • SUN2000-60KTL-HV-D1-001 - SUN2000HA V100R001
  • SUN2000-60KTL-M0 - SUN2000 V300R001C00
  • SUN2000-63KTL-JPH0 - SUN2000HA V200R001C00
  • SUN2000-63KTL-JPM0 - SUN2000 V300R001C00
  • SUN2000-65KTL-M0 - SUN2000 V300R001C00
  • SUN2000-70KTL-C1 - SUN2000 V300R001C00
  • SUN2000-70KTL-INM0 - SUN2000 V300R001C00
  • SUN2000-75KTL-C1 - SUN2000 V300R001C00
  • SUN2000-90KTL-H0 - SUN2000HA V200R001C00
  • SUN2000-90KTL-H1 - SUN2000HA V200R001C00
  • SUN2000-90KTL-H2 - SUN2000HA V200R001C00
  • SUN2000-95KTL-INH0 - SUN2000HA V200R001C00
  • SUN2000-95KTL-INH1 - SUN2000HA V200R001C00
  • SUN2000-100KTL-H0 - SUN2000HA V200R001C00
  • SUN2000-100KTL-H1 - SUN2000HA V200R001C00
  • SUN2000-100KTL-H2 - SUN2000HA V200R001C00
  • SUN2000-100KTL-INM0 - SUN2000 V500R001C00
  • SUN2000-100KTL-M0 - SUN2000 V500R001C00
  • SUN2000-100KTL-M1 - SUN2000 V500R001C00
  • SUN2000-100KTL-USH0 - SUN2000HA V200R001C00
  • SUN2000-105KTL-H1 - SUN2000HA V200R001C00
  • SUN2000-110KTL-M0 - SUN2000 V500R001C00
  • SUN2000-125KTL-JPH0 - SUN2000HA V300R001C00
  • SUN2000-125KTL-M0 - SUN2000 V500R001C00
  • SUN2000-168KTL-H1 - SUN2000HA V300R001C00
  • SUN2000-175KTL-H0 - SUN2000HA V300R001C00
  • SUN2000-185KTL-H1 - SUN2000HA V300R001C00
  • SUN2000-185KTL-INH0 - SUN2000HA V300R001C00
  • SUN2000-193KTL-H0 - SUN2000HA V300R001C00
  • SUN2000-196KTL-H0 - SUN2000HA V300R001C00
  • SUN2000-196KTL-H1 - SUN2000HA V300R001C00
  • SUN2000-196KTL-H3 - SUN2000HA V300R001C00
  • SUN2000-200KTL-H2 - SUN2000HA V300R001C00
  • SUN2000-215KTL-H0 - SUN2000HA V300R001C00
  • SUN2000L-2KTL - SUN2000L V100R001C00
  • SUN2000L-3KTL - SUN2000L V100R001C00
  • SUN2000L-3KTL-CN - SUN2000L V100R001C00
  • SUN2000L-3KTL-CN-4G - SUN2000L V100R001C00
  • SUN2000L-3.68KTL - SUN2000L V100R001C00
  • SUN2000L-4KTL - SUN2000L V100R001C00
  • SUN2000L-4KTL-CN - SUN2000L V100R001C00
  • SUN2000L-4KTL-CN-4G - SUN2000L V100R001C00
  • SUN2000L-4.125KTL-JP - SUN2000L V100R001C12
  • SUN2000L-4.6KTL - SUN2000L V100R001C00
  • SUN2000L-4.95KTL-JP - SUN2000L V100R001C12
  • SUN2000L-5KTL - SUN2000L V100R001C00
  • SUN2000L-5KTL-CN - SUN2000L V100R001C00
  • SUN2000L-5KTL-CN-4G - SUN2000L V100R001C00
  • SUN8000-500KTL - SUN8000 V100R001

Connect the Teleport to a Smartlogger

Modbus TCP over ethernet

The Teleport can be connected to the Smartlogger via a router or directly via the WAN port of the logger.

  1. Connect the ethernet cable between the ETH1 port of the Teleport and the router. Navigate to our appendix for generic instructions on how to integrate with a router. Make sure to note the IP of Teleport and the IP of the asset(s).

  2. Log in to the Smartlogger web UI, see Huawei documentation for login instructions. Note that you will need to have the username and password at your disposal. Note that if you want to set a fallback configuration extra steps apply.

  3. Go to Settings and choose Comm. Param

  4. Go to Modbus TCP and:

    • Change link setting to Enable(Limited)
    • Enter the IP of the Teleport (obtained from the router) in Client 1 IP Address
    • Set the Address Mode to Logical Address
    • Leave SmartLogger Address on 0. If the value is different, let us know the currently configured address. This is necessary to ensure the correct functioning of the Teleport.
  5. Go to Power Adjustment, select Active Power Control and:

    • Change Active power control mode to Remote communication scheduling.
    • Change Schedule strategy to Strategy 1.
    • Change Adjustment coefficient to 1.0.
    • Change Shutdown upon communication exceptions to Disable.
    Optional extra steps for fallback configuration
    1. Update smartlogger to version V300R023C00SPC152 or higher

    2. Go back to Power Adjustment, select the Active Power Control sub-menu and:

      • Change Limit solar inverter power upon active power scheduling timeout to Enabled.
      • Change Active power scheduling timeout threshold for triggering solar inverter power limiting to 60.
      • Change Power (in percentage of rated power) of solar inverter in case of active power scheduling timeout to target percentage.
      • Change Power (in percentage of rated power) of ESS in case of active power scheduling timeout to target percentage.
  6. Verify the individual inverters have remote control enabled using the following steps.

    1. Go to the Monitoring menu
    2. Select one of the inverters on the list
    3. Go to Running Param. and Power Adjustment menu and
      • Set Remote power schedule to Enable
      • Set Active power change gradient to 125
    4. Repeat steps 2 and 3 for all of the inverters

Direct connection via the WAN port of the SmartLogger

  1. Connect the ethernet cable between the ETH1 port of the Teleport and the WAN port of the Huawei SmartLogger.

  2. Log in to the Smartlogger web UI, see Huawei documentation for login instructions. Note that you will need to have the username and password at your disposal. Note that if you want to set a fallback configuration extra steps apply.

  3. Go to Settings and choose Comm. Param

  4. Go to Wired Network and verify that the WAN Port Parameters are on the factory default (IP Address: 192.168.0.10, Subnet Mask: 255.255.255.0). If the settings are different, please inform us of the exact settings. This is necessary to ensure the correct functioning of the Teleport.

  5. Go to Modbus TCP and:

    • Change link setting to Enable(Limited)
    • Enter 192.168.0.11 (the IP of the Teleport) in Client 1 IP Address. Note that if the WAN Port Parameters of the logger in point 4. are not on the factory default, Teleport will have to be manually reconfigured to a different IP address, and this step will have to be done again.
    • Set the Address Mode to Logical Address
    • Leave SmartLogger Address on 0. If the value is different, let us know the currently configured address. This is necessary to ensure the correct functioning of the Teleport.
  6. Go to Power Adjustment, select the Active Power Control sub-menu and:

    • Change Active power control mode to Remote communication scheduling.
    • Change Schedule strategy to Strategy 1.
    • Change Adjustment coefficient to 1.0.
    • Change Shutdown upon communication exceptions to Disable.
    Optional extra steps for fallback configuration
    1. Update smartlogger to version V300R023C00SPC152 or higher

    2. Go back to Power Adjustment, select the Active Power Control sub-menu and:

      • Change Limit solar inverter power upon active power scheduling timeout to Enabled.
      • Change Active power scheduling timeout threshold for triggering solar inverter power limiting to 60.
      • Change Power (in percentage of rated power) of solar inverter in case of active power scheduling timeout to target percentage.
      • Change Power (in percentage of rated power) of ESS in case of active power scheduling timeout to target percentage.
  7. Verify the individual inverters have remote control enabled using the following steps.

    1. Go to the Monitoring menu
    2. Select one of the inverters on the list
    3. Go to Running Param. and Power Adjustment menu and
      • Set Remote power schedule to Enable
      • Set Active power change gradient to 125
    4. Repeat steps 2 and 3 for all of the inverters

Connect the Teleport to Inverter(s)

The Teleport can connect to inverters directly or through the Huawei SDongleA-05. For connection through the SDongleA-05, the firmware of both the inverter and the SDongleA-05 should be updated to the latest version prior to the installation, and the SDongleA-05 should have Modbus TCP enabled.

  1. Connect the serial cable between the serial port of the Teleport and the serial port of the master inverter (first inverter in case of cascading). Depending on the configuration, Teleport can connect to up to 3 strings of inverters.

  2. Log in to the inverter over a USB cable and log in as an advanced user. Note that you will need to have the username and password at your disposal.

  3. Go to Settings and then choose Feature Parameters. Navigate to RS485-1 communication (or RS485-2 communication) and select Enable. Note that both RS485-n communication interfaces should have the same configuration.

  4. For the connected RS485 interface, verify that each inverter has the following settings:

    • Protocol type: Modbus
    • Port mode: Slave mode
    • Baud rate: 9600
    • Parity: none
    • Stop bit: 1
  5. In the case of a single inverter, verify the Com address is 1. In case of multiple inverters, please set each inverter in a string to a different address and let us know these addresses. This is necessary to ensure the correct functioning of the Teleport.

Using an SDongleA-05

  1. Log to the SDongleA-05 interface with the Huawei SUN2000 app.
  2. Go to Settings > Communication configuration and Dongle parameter settings.
  3. Select Modbus TCP and select Enable Unrestricted.
  4. On the inverter, verify the Com address is 1.
  5. Let us know the IP address of the SDongle.