Specifications
Interfaces
| Cellular | LTE Cat 1 (4G) |
| LAN | 100 Mbps ethernet port, RJ45 connector (2x) |
| Serial | RS-485 half-duplex (1x) RS-485 half-duplex, galvanic isolation from the other RS-485 interfaces (up to 2x) |
Services
By default the Teleport exposes the following services:
| Port | Transport protocol | Protocol | Notes |
|---|---|---|---|
| 22222 | TCP | SSH | Incoming connections will be rejected |
Next to that, on request specific services like a Modbus service can be exposed.
Electrical specifications
| Power supply | 8 VDC to 36 VDC |
| Power supply unit | 100 VAC to 240 VAC, 50 Hz or 60 Hz input with EU, UK, US, or AU plug 12 VDC, 3 A output |
| Power consumption | 2.6 W to 7.2 W, depending on the system load |
Mechanical specifications
| Enclosure | 112mm x 84mm x 25mm |
| Case | Aluminium housing |
| Weight | 450 gram |
Redundant rack-mount unit
The redundant rack-mount unit has the following specifications. The specifications above apply to each of the two Teleports inside the unit.
| Dimensions | 19" 3U |
| Teleports | 2x (primary + backup) |
| Power supplies | 2x Mean Well HDR-15-24 (100 VAC to 240 VAC input, 24 VDC / 15 W output), each fed by a C14 power cord |
| Failover relay | F&F MR-RO-1 (automatic) |
Reliability and environmental
| MTTF | > 200,000 hours |
| Warranty | 24 months |
| Operating temperature | Industrial Certified (TIC) -40°C to 80°C |
| Storage temperature | -40°C to 85°C |
| Relative humidity | 10% to 90% (operation) 5% to 95% (storage) |