Solax Power
The Teleport can connect to the Solar-Log Base products included in the list of supported models below. You can connect with Modbus RTU using RS485 serial interface.
Supported models
- X3-MIC G2
- A1-Hybrid-6.0-US
- A1-Hybrid-7.0-US
- A1-Hybrid-7.6-US
- A1-Hybrid-8.6-US
- A1-Fit-6.0-US
- A1-Fit-7.0-US
- A1-Fit-7.6-US
- A1-Fit-8.6-US
- A1-6.0-US
- A1-7.0-US
- A1-7.6-US
- A1-8.6-US
Supported properties
- generatedEnergy
- activePower
- activePowerLimit.percentage
- inverters[].activePower
- inverters[].generatedEnergy
Modbus RTU over RS485
- 
Connect the serial cable between the serial port of the Teleport and the serial port of the Solax inverter. 
- 
On the inverter’s LCD display, go to Settings, follow the inverter’s user manual to enter the password, and then navigate to RS485 CommAddr. In the case of a single inverter, verify the COM Address is 1. In the case of multiple inverters, please set each inverter to a different address and let us know these addresses.
- 
Navigate to Modbus Function and set it to COM485.
- 
Navigate to ParallelSetting and set it to Disable.