Solax Power
The Teleport can connect to the Solar-Log Base products included in the list of supported models below. You can connect with Modbus RTU using RS485 serial interface.
Supported models
X3-MIC G2
A1-Hybrid-6.0-US
A1-Hybrid-7.0-US
A1-Hybrid-7.6-US
A1-Hybrid-8.6-US
A1-Fit-6.0-US
A1-Fit-7.0-US
A1-Fit-7.6-US
A1-Fit-8.6-US
A1-6.0-US
A1-7.0-US
A1-7.6-US
A1-8.6-US
Modbus RTU over RS485
-
Connect the serial cable between the serial port of the Teleport and the serial port of the Solax inverter.
-
On the inverter’s LCD display, go to Settings, follow the inverter’s user manual to enter the password, and then navigate to RS485 CommAddr. In the case of a single inverter, verify the COM Address is
1
. In the case of multiple inverters, please set each inverter to a different address and let us know these addresses. -
Navigate to Modbus Function and set it to
COM485
. -
Navigate to ParallelSetting and set it to
Disable
.