The Teleport can connect to Alpitronic Hypercharger charging stations using Modbus TCP.

Supported models
  • HYC50
  • HYC150
  • HYC200
  • HYC300
  • HYC400

External control of the charging station must be activated in the configuration menu via the web page of the charging station. To do so, you have to follow these steps:

  1. Go to the IP address and log in with your user and password.

  2. In the main page of the settings of the charging station:

    • Go to General
    • Go to Power
    • Set ModBus Enabled to true
    • Click on Save Settings
  3. Activate the changes made by Resetting the charging station.

    • Go back to the main page
    • Check that there are no cars connected to the charging station
    • Go to Reset
    • Choose Soft Reset HYC